Flexible Copper Stranded Wires 0.05mm (AWG44)

CONSTRUCTION AND APPLICATION BGTS(X) and BGTSR type flexible copper stranded wires for electric brush consists of annealed highly flexible Cu-ETP copper wires, and can be used for flexible connection

CONSTRUCTION AND APPLICATION

BGTS(X) and BGTSR type flexible copper stranded wires for electric brush consists of annealed highly flexible Cu-ETP copper wires, and can be used for flexible connection of motor, electrical apparatus and instrument wiring, specially for AC current or high-frequency current.

Standard: GB/T12970.4-2009.

TECHNICAL DATA

Material: annealed Cu-ETP wires, C11000, copper content ≥ 99.95%

Finish: bare, tin plating

Packing Modes: in rolls, on spools or wooden drums

TYPE AND SPECIFICATION

Type Single Wire Diameter   Elongation, not less than
BGTS 0.10mm (AWG38 ), 0.12mm 18%
BGTSX 0.10mm (AWG38 ), 0.12mm 15%
BGTSR 0.05mm (AWG44), 0.07mm(AWG41) 15%

MODEL AND MEANING

Flexible Copper Stranded Wires 0.05mm (AWG44)

Customization Upon Request

Round Type: Single Wire Diameter: 0.07mm(AWG41)

Part No. Nominal Cross Section (mm2) Calculating Cross Section (mm2) Structure Calculating Outside diameter (mm) Max. DC Resistance at 20℃
Ω/km
Calculating weight(kg/km)
Total Wire Number Strands×Wire Number Per Strand/Single Wire Diameter (mm) BGTSR BGTSRX
BGTSR(X)-2 2 1.93 504 7×72/0.07 2.2 9.16 9.65 18.3
1.93 504 7×3×24/0.07 2.2 9.16 9.65 18.6
BGTSR(X)-3.5 3.5 3.47 903 7×3×43/0.07 2.7 5.35 5.51 33.3
BGTSR(X)-4 4 4.01 1044 12×3×29/0.07 2.9 4.59 4.83 39.0
4.03 1050 7×3×50/0.07 3.0 4.59 4.83 39.0
BGTSR(X)-5 5 4.84 1260 7×3×60/0.07 3.2 3.71 3.86 46.5
5.02 1305 15×3×29/0.07 3.2 3.71 3.86 48.5
BGTSR(X)-6 6 5.65 1470 7×3×70/0.07 3.6 2.93 3.21 54.2
BGTSR(X)-8 8 7.75 2016 12×3×56/0.07 4.2 2.33 2.44 73.0
BGTSR(X)-10 10 9.69 2520 12×3×70/0.07 4.8 1.83 1.91 90.5
BGTSR(X)-12 12 11.90 3096 12×3×86/0.07 5.4 1.50 1.60 112.2
BGTSR(X)-16 16 15.34 3990 19×3×70/0.07 6.2 1.16 1.21 150.5

Round Type: Single Wire Diameter: 0.05mm (AWG 44) 

Part No. Nominal Cross Section (mm2) Calculating Cross Section (mm2) Structure Calculating Outside diameter (mm) Max. DC Resistance at 20℃
Ω/km
Calculating weight(kg/km)
Total Wire Number Strands×Wire Number Per Strand/Single Wire Diameter (mm) BGTSR BGTSRX
BGTSR(X)-1 1 0.99 504 7×3×24/0.05 1.4 18.5 19.3 9.3
BGTSR(X)-1.3 1.3 1.32 672 7×3×32/0.05 1.7 14.2 14.8 12.5
BGTSR(X)-1.5 1.5 1.48 756 7×3×36/0.05 1.8 11.9 12.7 14.0
BGTSR(X)-1.8 1.8 1.81 924 7×3×44/0.05 2.0 10.2 10.7 17.5
BGTSR(X)-2 2 1.98 1008 7×3×48/0.05 2.2 9.16 9.65 19.0
BGTSR(X)-2.5 2.5 2.30 1176 7×3×56/0.05 2.3 7.39 7.72 22.5
BGTSR(X)-3 3 2.95 1505 7×5×43/0.05 2.6 6.16 6.43 29.0
BGTSR(X)-4 4 3.95 2016 12×3×56/0.05 2.7 4.59 4.83 39.0
BGTSR(X)-5 5 4.94 2520 15×3×56/0.05 3.2 3.71 3.86 48.5
BGTSR(X)-6 6 6.26 3192 19×3×56/0.05 3.6 2.93 3.21 60.0
BGTSR(X)-8 8 8.05 4104 19×3×72/0.05 4.2 2.33 2.44 78.5
BGTSR(X)-10 10 10.00 5096 7×7×104/0.05 4.8 1.83 1.91 97.0
10.07 5130 19×3×90/0.05 4.8 1.83 1.91 97.8
BGTSR(X)-12 12 12.08 6156 19×3×108/0.05 5.4 1.50 1.60 117.0